The Frigidaire FGHB2844LF7 is a 27.8 Cu. Ft. French Door Refrigerator with bottom freezer, featuring EvenTemp cooling, PureAir Ultra II filter, and SpaceWise organization. This service manual provides technical information for qualified technicians, including diagnostics, wiring diagrams, component testing, disassembly, and parts lists. Intended for trained personnel only. Powered by 120V AC, 15A circuit. For official support, contact Frigidaire service at 1-800-374-4432. Below are key sections for repair and maintenance.
WARNING! Disconnect power before servicing to prevent electrical shock. Discharge capacitors. Wear safety gear. Handle refrigerant per EPA regulations (R-134a). Do not bypass safety controls. Use only OEM parts.
CAUTION! High voltages present; two-person lift for heavy components. Avoid ESD on electronics.
DANGER! Refrigerant under pressure; use recovery equipment. Fire hazard with flammable materials.
Enter service mode: Press and hold Freezer and Refrigerator temp buttons for 5 seconds (display "SY"). Cycle through tests with up/down arrows. Tests include: Compressor run, fans, defrost heater, lights, sensors.
Tools Needed: Multimeter, thermometer, amp clamp, manifold gauge set.
| Code | Description | Action |
|---|---|---|
| SY EF | Evaporator Fan Failure | Test fan motor, wiring, control board. |
| SY CE | Freezer Temp Sensor Error | Check sensor resistance (10k ohm @ 77°F), replace if open. |
| SY dE | Defrost Error | Test heater (30-50 ohm), thermostat (closes @ 40°F). |
| SY HS | High Side Pressure | Check condenser fan, clean coils. |
| OP | Door Open | Check switch alignment. |
| PF | Power Failure | Clear after restoring power. |
Compressor: Locked rotor amps 5-7A start, 1-2A run. Check windings: Run 3-5 ohm, Start 5-10 ohm, Common 0 ohm.
Evaporator Fan: 120V, 0.5A, spins freely, 50-100 RPM.
Defrost Heater: 300-500W, resistance 25-40 ohm.
Thermistors: 10k NTC, resistance chart: 32°F=32k, 77°F=10k, 104°F=3.3k ohm.
Water Inlet Valve: 120V solenoid, 500 ohm coil.
Refer to schematic in back: Main harness connects control board (EOC) to compressor, fans, heater, sensors. Power: Black to L1, White to N. Ground green. Low voltage: 5VDC for sensors. Ice maker: 120V via harness.
Key Connections: J1 (Power), J2 (Sensors), J3 (Outputs).
| Wire Color | Function |
|---|---|
| Black | Line Hot |
| White | Neutral |
| Blue | Evap Fan |
| Yellow | Defrost Heater |
| Red | Cond Fan |
Control Board: Remove top grille, disconnect harness, unclip board.
Evaporator Fan: Remove rear panel in freezer, disconnect, slide out assembly.
Compressor: Recover refrigerant, remove lower access panel, cut lines, unbolt.
Doors: Remove top hinge, lift off, transfer hardware.
Ice Maker: Unplug harness, release mounting screws.
Single evaporator, capillary tube, hot gas bypass for defrost. Pressures: Low 0-5 PSIG cut-in, 20-30 cut-out; High 150-250 PSIG. Charge: 6.5 oz R-134a. Leak test with nitrogen, evacuate to 500 microns.
Sealed System Repair: Requires brazing, recovery station. Replace filter-drier always.
Refer to exploded views. Common parts: Compressor (5303919037), Evap Fan Motor (5304460131), Control Board (5304495668), Thermistor (5303930015).
| Section | Key Parts |
|---|---|
| Cabinet | Top Hinge (240423401), Leveling Leg (5308000010) |
| Doors | Gasket (242193231), Handle (242126602) |
| Evaporator | Heater (5308000014), Cover (5303921067) |
| Controls | Board (5304495668), Display (241707601) |
| Ice Maker | Assembly (5303917276), Valve (5303918201) |
| Symptom | Cause | Action |
|---|---|---|
| No Cooling | Compressor not running, low charge. | Check voltage 120V, amps 1A run; pressures. |
| Freezer Frosted | Defrost failure. | Test heater/thermostat; advance defrost. |
| Noise | Fan rubbing, loose panels. | Inspect fans, tighten screws. |
| No Ice | Valve solenoid, maker module. | Check 120V to valve, cycle maker. |
| Water Leak | Clogged drain, faulty valve. | Clear drain tube; test valve. |
| Control Issues | Board fault, sensor open. | Replace board if tests pass; check resistance. |
Reset: Unplug 5 min, or cycle power. For sealed system, call authorized tech.
Service Contact: 1-800-374-4432; www.frigidaire.com