The Frigidaire FGHD2472PF is a 24" Built-In Gallery Series Dishwasher featuring OrbitClean wash system, Sanitize option, adjustable racks, third rack, and quiet 47 dB operation. This service manual provides technical information for qualified technicians, including diagnostics, wiring diagrams, component testing, disassembly, and parts lists. Intended for trained personnel only. Powered by 120V AC, 15A circuit. For official support, contact Frigidaire service at 1-800-374-4432. Below are key sections for repair and maintenance.
WARNING! Disconnect power and water supply before servicing to prevent shock or injury. Discharge capacitors if present. Wear safety gear. Handle with care to avoid sharp edges. Use only OEM parts. Comply with local codes and EPA for any chemical handling.
CAUTION! High temperatures in heating elements; allow cooling. Two-person lift for heavy assemblies.
DANGER! Risk of electrical shock; do not bypass interlocks.
Enter diagnostic mode: Open door, press Hi-Temp + Delay Start + Power (within 5 sec). LED flashes. Cycle through tests: 1-Fill, 2-Drain, 3-Wash motor, 4-Heater, 5-Dispenser, 6-Sensors. Exit: Power off.
Tools: Multimeter, amp probe, thermometer, manometer for water pressure.
| Code | LED Indication | Description | Action |
|---|---|---|---|
| i20 | Wash + Dry | No fill (no water) | Check inlet valve, screen, pressure switch. |
| i30 | Wash + Heat Dry | Leak detected | Inspect tub seal, drain hose; check float switch. |
| i40 | Normal + Heat Dry | No drain | Test drain pump (120V, 2A); clear impeller. |
| H20 | Normal + Hi-Temp | Heater failure | Check element (15-20 ohm), thermostat. |
| Er | All LEDs | Board error | Reset; replace control board if persists. |
| d01 | Door | Door open | Check latch switch continuity. |
Inlet Valve: 120V solenoid, 800-1200 ohm coil; check for 120V during fill.
Drain Pump: 120V, 2-3A run; spins freely, no hum.
Heating Element: 1400W, 10 ohm resistance; continuity test.
Hi-Limit Thermostat: Opens at 190°F, closes 150°F; resistance infinite when open.
Wash Motor: 120V, 1.5A; check capacitor (5uF), impeller free.
Door Switch: Continuity when closed.
Pressure Switch: Dry: open, wet: closed (tests fill level).
Main harness: J1 power (L/N/GND), J2 controls, J3 motor/heater. Low voltage 12VDC for board. Refer to schematic: Black-L, White-N, Green-GND. Dispenser: 12V solenoid.
| Wire Color | Function |
|---|---|
| Black | Line Hot |
| White | Neutral |
| Blue | Wash Motor |
| Red | Drain Pump |
| Yellow | Heater |
| Green | Ground |
Control Panel: Remove screws from door front, disconnect harness, unclip.
Door Latch/Switch: Open door, remove inner panel screws, disconnect wires.
Lower Spray Arm/Pump: Remove lower rack, twist arm off; access pump via tub base, unbolt.
Heating Element: Drain unit, remove lower access, disconnect, unclip bracket.
Filter/Sump: Twist filter out; remove sump cover screws.
Upper Rack/Rail: Pull out, release stop clips.
Water inlet: 1/4" brass connector, screen filter. Drain: 5/8" hose, air gap recommended. Electrical: Junction box at rear, 12" whip. Test continuity from board to components. Pressure test: 20 PSI min.
Leak Test: Run cycle, inspect all seals.
Refer to exploded views. Common parts: Control Board (5304475580), Inlet Valve (5304475581), Drain Pump (5304475582), Heater (5304475598), Door Latch (5304475570).
| Section | Key Parts |
|---|---|
| Control | Board (5304475580), Panel (5304475569) |
| Door | Latch (5304475570), Gasket (5304475599) |
| Tub | Spray Arm Lower (5304475600), Upper (5304475601) |
| Pump | Drain Pump (5304475582), Wash Impeller (5304475583) |
| Heater | Element (5304475598), Thermostat (5304475596) |
| Racks | Lower Rack (5304475624), Upper Rack (5304475625) |
| Symptom | Cause | Action |
|---|---|---|
| No Fill | Valve solenoid fail, no power. | Check 120V at valve; replace if no continuity. |
| No Drain | Pump clogged, wiring. | Clear debris; test 120V/2A. |
| Dishes Not Clean | Low water temp, blocked arms. | Verify 120°F inlet; clean arms. |
| No Heat/Sanitize | Element open, thermostat. | Test resistance; replace. |
| Noisy | Impeller bind, loose parts. | Inspect motor; tighten. |
| Door Won't Latch | Worn mechanism. | Replace latch assembly. |
| Control Unresponsive | Board fault. | Diagnostic test; replace board. |
Reset: Unplug 5 min, cycle power. For persistent issues, replace main control.
Service Contact: 1-800-374-4432; www.frigidaire.com